With LCD controlling system, 3 way water quality sensor, built-in 2 water tanks, 3 pump, and 2 stage RO system, Dura 12/24 series is sub-top choice of ultrapure water for high grade experiments.
With tap water inlet, its output ranges from 12 to 24 liters/hour. It can produce 2nd stage RO water and ultrapure water. The 2nd stage RO water’s conductivity can stay 1-5μs/cm, and the ultrapure water’s resistivity absolutely reaches to 18.2MΩ.cm. It completely meets the highest grade I standard of ASTM, CAP, CLSI, EP and USP.
Models:
Dura 12 / 24
Dura 12 / 24F
Dura 12 / 24V
Dura 12 / 24FV
Features and Advantages
Micro-computer control system with LCD display LCD (resolution: 240×128, dimension: 106×57mm), intuitively display the system running state and various real-time parameters. |
|
Comprehensive monitoring system 3 way online water quality sensor, detect the quality of feed water, 2nd stage RO water / deionized water, and ultrapure water respectively. And warn once water quality´s standard exceeding. |
|
Built-in 2 water tanks and 3 pumps Built-in 5.8 liters PE tank and 10 liters airtight plastic pressure water tank, save more lab space. Built-in 1st stage 2nd stage RO pump and circulating sanitizing pump. |
|
Double stage reverse osmosis technology With 2 pumps, 2 RO membranes and buffer tank, system assures 2nd stage RO water quality´s stability from different source water, and achieves little drain and low running cost. |
|
Easy-to-replacing cartridge Integrated design of pretreatment and subsequent purification unit. New card hawk type fast inserted interface, easy to replace. |
|
4 door design and easy-to-maintaining Convenient to maintain system and replace cartridges. |
Cartridges replacing alarm function, based on time and water quality, show cartridges´ used and residual life.
Multiple alarm function: no feed water, full water, water quality´s standard exceeding, and cartridge life ending.
Auto self-flushing of RO membrane function, extend RO membrane´s life.
Auto running data storing function through RS232/USB communication port to computer for 1 year at least.
System sanitizing procedure, achieve the disinfection of ultrapure water´s tube and valve.
System circulation function, achieve ultrapure water´s circulation to keep top quality of ultrapure water.
Level II password, protect all the parameters setting, and prohibit any unauthorized setting change.
Water dispensing function- timing and quality (time range: 1-99min, water quality range: 0.1-18.2MΩ.cm).
External water tanks is optional to meet different need and assure ample water-supply.
Whole plastic shell with high-strength, avoid rusting and keep clean, to meet GLP standard.
Tube and adapter with NSF authorization and top quality, reduce TOC level and assure ultrapure water´s quality.
Optimized pretreatment (including PP fiber, KDF and active carbon cartridge), effectively protect RO membrane.
RO module with DOW´s membrane, ensure long life, stable operation and high desalinization rate.
Ultrapure cartridge with DOW´s top polishing resin, ensure ultrapure water´s quality up to 18.2 MΩ.cm, with the lowest TOC level.
Double wavelength (185&254nm) ultraviolet lamp module, restrain bacteria´s increase and reduce TOC.
MWCO 5000D ultrafiltration module, effectively eliminate endotoxin, and suitable for precise cell cultivating and IVF.
(0.45+0.1)µm double layer PES terminal disinfection filter, assure that terminal pure water is absolutely axenic.
Flow Schematic
Specifications
Model |
Standard |
Eliminating endotoxin |
Low TOC |
Synthesizing |
Dura 12 |
Dura 12F |
Dura 12V |
Dura 12FV |
|
Dura 24 |
Dura 24F |
Dura 24V |
Dura 24FV |
|
Output -2nd stage RO water* |
12 or 24 liters/hour |
|||
Output -ultrapure water |
Up to 2 liters/minute (when tank is full) |
|||
Ultrapure water quality |
||||
Resistivity (25°C) |
18.2MΩ.cm |
|||
TOC* |
<10ppb |
<10ppb |
<3ppb |
<3ppb |
Bacteria |
<0.01cfu/ml |
|||
Particle (>0.01µm) |
<1/ml |
|||
Endotoxin |
N/A |
>0.001Eu/ml |
N/A |
>0.001Eu/ml |
RNases |
N/A |
<1pg/ml |
N/A |
<1pg/ml |
DNases |
N/A |
<5pg/ml |
N/A |
<5pg/ml |
RO water quality |
||||
Conductivity - 1st stage RO water |
Feed water conductivity×5%* |
|||
Conductivity - 2nd stage RO water |
1-5µs/cm* |
|||
Feed water requirements |
Tap water, temperature: 5-45°C, pressure: 1.0-4.0Kgf/cm2 |
|||
Dimension and weight |
Length×Width×Height: 545×470×610mm / Weight: 25Kg |
|||
Electrical requirements |
AC200-240V, 50/60Hz |
|||
Power |
240W |
|||
Standard configuration |
Main body (Including 1 set of cartridge) + built-in 12 liters pressure tank |
Remarks:
*The value will be influenced by temperature and feed water’s quality.
Cartridges
Item no. |
Commodity |
Approximate replacement term /set |
D-PP1 |
Pretreatment cartridge |
2-6 months |
D-AK |
KDF+ granular active carbon mixed cartridge |
12 months |
D-AC2 |
Active carbon block cartridge |
6 months |
D-RO-50 |
50 GPD reverse osmosis membrane |
12-24 months |
D-RO-100 |
100 GPD reverse osmosis membrane |
12-24 months |
D-RO-150 |
150 GPD reverse osmosis membrane |
12-24 months |
D-RO-200 |
200 GPD reverse osmosis membrane |
12-24 months |
D-Uvlamp-14W |
(254&185) nm wavelength uv lamp |
9000 hours |
D-Decart |
Mixed bed resin cartridge |
5000 liters pure water |
D-Pocart4 |
Ultrapure polishing resin cartridge |
5000 liters pure water |
D-Ufcart |
Eliminating endotoxin uf cartridge |
- |
D-Tefit |
(0.45+0.1µm) terminal filter |
- |
Remarks:
*The quality of inlet water will effect cartridge’s life.
*When inlet water’s TDS>200ppm, Replace term of filter will be suggested to decrease, or outside pre-filter is added. Or water quality and life of ultrapure cartridge will be affected.
HHitech-Products
Designing and manufacturing under ISO certification, top quality controlling commitment, ensure compliance with CE standards of EU, guarantee completely meeting with the highest grade I water standards of ASTM, CAP, CLSI, EP and USP.
HHitech-Service
As a responsible manufacturer with rich experience, operating in good faith, and the concept of common development, adhering to the customer-oriented and customer-needs, HHitech promises to provide professional comprehensive pre-sales and after-sales service in the whole business.
■ 12 months warranty except for consumables.
■ Timely guide for installation, usage and maintenance.
■ Free and continuous upgrade service for sold products.
http://www.hhitechlabwater.com/